Product Model WBC-9.5HP-B (BB-L1) WBC-16.0HP-B (BB-L1) WBC-19.0HP-B (BB-L1) WBC-26.0HP-B (BB-L1) Model Code 3P 5P 8F 8F Nominal heating condition
A-12°C A-14°C
W 36-41°CHeating capacity KW 5.40 9.00 11.80 14.40 Energy efficiency ratio COP 2.30 2.20 2.38 2.90 Input power KW 2.35 4.09 6.06 6.26 Input current A 11.22 19.87 24.23 25.96 heating condition
A 7°CA 6°C
W 40-45°CHeating capacity KW 9.00 15.20 17.60 24.00 Energy efficiency ratio COP 3.10 3.10 3.05 3.20 Input power KW 2.95 4.90 6.77 7.50 Input current A 12.12 23.48 27.61 26.89 heating condition
A 7°CA 6°C
W 36-41°CHeating capacity KW 8.97 15.26 18.34 25.32 Energy efficiency ratio COP 1.67 3.57 3.50 3.52 Input power KW 2.45 3.94 6.23 7.18 Input current A 11.70 19.87 25.03 24.92 heating condition
A0°C A-3°C
W 36-41°CHeating capacity KW 7.26 13.22 16.13 21.02 Energy efficiency ratio COP 3.02 3.33 3.21 3.10 Input power KW 2.40 3.90 6.02 7.07 Input current A 11.51 19.64 24.03 33.83 heating condition
A-6°C A-8°C
W 36-41°CHeating capacity KW 6.25 11.55 13.80 18.78 Energy efficiency ratio COP 2.39 2.97 2.69 2.56 Input power KW 2.38 3.89 5.06 7.12 Input current A 11.81 16.62 24.23 28.08 Nominal heating condition
A-20°C A-21°C
W 36-41°CHeating capacity KW 4.80 6.52 8.90 13.04 Energy efficiency ratio COP 1.65 1.57 2.09 - Input power KW 2.21 3.53 4.76 6.24 Input current A 10.58 9.67 22.79 29.85 Comprehensive partial load performance coefficient (heating) IPLV(H) 2.50 2.60 2.60 2.70 Electric Heater Power kW 4.43 7.35 8.68 11.25 Max Input Power kW 4.43 7.35 8.68 11.25 Max Input Current A 21.18 35.19 11.42 53.83 Power Supply V/PH/HZ 220V/1PH/50Hz 220V/1PH/50Hz 220V/1PH/50Hz 220V/1PH/50Hz Operating Temperature Range °C 25 to -45 25 to -45 25 to -45 25 to -45 Water Flow Rate (ΔT=5°C) m³/h 0.93 1.55 2.03 2.48 Water Pressure Drop kPa 20 40 40 40 Rated Outlet Water Temperature °C 41 41 41 41 Max Outlet Water Temperature °C 60 60 60 60 Water Connection G1 (Right Side) G1 (Left Side) G1 (Right Side) G1.5 (Rear) Water Pump None None None None Compressor Quantity 1 1 1 1 Fan Quantity 1 1 1 1 Noise dB(A 58 60 60 60 Unit Dimensions(L/W/H) mm) 1120/1200/545 1120/1300/1205 1120/1430/1205 1120/1430/1205 Net/Gross Weight kg 105 148 154 197 Rated heating test conditions; The inlet/outlet temperature on the air conditioning side is 40 ℃/45 ℃, and the ambient dry/wet bulb temperature is 7 ℃/6 ℃;
The model, parameters, and performance may change due to product improvements without prior notice. Please refer to the nameplate for specific parameters.
Variable frequency low-temperature side air outlet - integrated variable frequency family style cooling and heating dedicated unit
If you need customized products, Contact US !
Category
Tag list
Request a Quote
We will contact you within one working day. Please pay attention to your email.